Operating Instructions – MOVIMOT® MM03C - MM3XC

8

Selectable special functions MM..C-503-30

Startup with Integrated AS-Interface

Influencing the cur-
rent characteristic
curve

By selecting a lower current limit, the calculation of the current limit is carried out with a
constant factor.

Motor with star connection

Motor with delta connection

50851AXX

[1] Current limit characteristic curve of standard function
[2] Reduced current limit characteristic curve for special function 3 and AS-i bit "speed f1/
speed f2"= "1"

50852AXX

[1] Current limit characteristic curve of standard function
[2] Reduced current limit characteristic curve for special function 3 and AS-i bit "speed f1/
speed f2"= "1"

200

160

100

50

0

50

100 f [Hz]

I

max

/ I

n

[%]

[1]

[2]

200

160

100

50

0

50

100

87

I

max

/ I

n

[%]

f [Hz]

[1]

[2]