Operating Instructions – MOVIMOT® MM03C - MM3XC

5

Connection MOVIMOT® options

Electrical Installation of MOVIMOT® Standard Design

Connection of
MBG11A option

The following figure shows the connection of the MBG11A option.

Connection of
MLK11A option

The following illustration shows the connection of the MLK11A option (external AS-i bi-
nary slave).

03183CXX

[1] Observe the enabled direction of rotation (see the section "Connection of MOVIMOT

®

basic unit, Functions of CW/Stop, CCW/Stop terminals with control via RS-485 interface.")

[2] EMC metal cable gland

MBG11A

24V

RS+

RS-

13

14

15

L1

L2

L3

24V

R

L

f1/f2

K1a

K1b

RS-

RS+

MOVIMOT

®

24 V

DC

[2]

[1]

05118CXX

[1] AS-i connection
[2] Connection for two external sensors

4

2

1

3

13

14

15

L1

L2

L3

24V

R

L

f1/f2

K1a

K1b

RS-

RS+

MLK11A

2

1

3

4

5

[2]

AS-i +

AS-i -

24V

DI2

0V

N.C.

N.C.

N.C.

DI3

MOVIMOT

®

[1]

WH

BK/BU

BK/RD

BK/WH

RD

BU

(DI0)

(DO2)

(DO1)

(DO0)

(DO3)

(

)