Connection of movimot, Mm../avsk (connection option a), Mm../avsk – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 42

Advertising
background image

42

Operating Instructions – MOVIMOT® MM03C - MM3XC

6

Connection of MOVIMOT® MM../AVSK (connection option A)

Electrical Installation with Integrated AS-Interface

6.3

Connection of MOVIMOT

®

MM../AVSK (connection option A)

The following figure shows the connection of the MM../AVSK design.

51823AXX

[1] 24 V

DC

supply

[2] AS-i data cable -
[3] AS-i data cable +
[4] Voltage supply for sensors
[5] Sensor DI2
[6] Sensor DI3
[7] BW.. braking resistor (in MOVIMOT

®

without mechanical brake only)

[8] M12 plug (yellow)

M

3~

L1
L2
L3
PE

K11

F11/F12/F13

13

14

15

L1

L2

L3

24V

AS-i -

AS-i +

VO

VO24

DI2

DI3

BMG

RD

WH

BMG

[1] [2] [3]

[4]

[5]

[6]

BL

BW.

[7]

4

2

1

3

3

1

4

2

AS-I+

AS-I- 24 V

[8]

MM../AVSK