Product overview

2.11.2

EP2809­0022 ­ Introduction

Fig. 33: EP2809­0022

16 digital outputs 24 V

DC

, I

max

 0.5 A (Σ 4 A)

The EP2809­0022 EtherCAT Box with digital outputs connects the binary control signals from the controller
on to the actuators at the process level.

The 16 outputs handle load currents of up to 0.5 A each, although the total current is limited to 4 A. This
makes these modules particularly suitable for applications in which not all of the outputs are active at the
same time, or in which not all of the actuators draw 0.5 A current.

The signal state is indicated by means of light emitting diodes. The signals are connected via M12
connectors. All outputs are short­circuit­proof and protected against inverse connection.