1 Front feeding point

Via this parameter the feeding point is set.

The set value determines the reference point of the seam.

Input:

135, 225, 315 mm

Factory setting:

2 Feeding speed

Via this parameter the clamping speed from the feeding position to the
sewing start position is set.

As soon as the photocell is active, the speed is reduced by half to
enable a precise scanning. When processing fleece material the speed
is reduced to a third.

Input:

10 - 90%

Factory setting:

60%

3 Speed at the seam beginning

Via this parameter the speed of the machine head is set.
It it dependent on the needle and centre knife switching.

Input:

500 - 2000 rpm

Factory setting:

1500 rpm

4 Speed within the seam

Via this parameter the speed within the seam is set.

Input:

500 - 3000 rpm

Factory setting:

2500 rpm

5 Speed at the seam end

via this parameter the speed at the seam end is set.

Input:

500 - 2000 rpm

Factory setting:

1500 rpm

6 Seam section speed at the seam beginning

Via this parameter the seam section at the seam beginning to be sewn
with the “speed of the seam beginning” is set.

Input:

0 - 99 mm

Factory setting:

5 mm

7 Seam section speed at the seam end

Via this parameter the seam section at the seam end to be sewn with
the “speed of the seam end” is set.

Input:

0 - 99 mm

Factory setting:

5 mm

8 Stitch length seam beginning

via this parameter the stitch length for bartacks or stitch condensing at
the seam begining is set.

Input:

0.5 - 3 mm

Factory setting:

1.5 mm