2.1.1

Position of the limit switch in the slotted hole

Checking
–

Unscrew the screws 8 and take off the covering cap 9.

–

Check the position of the limit switch 1 in the slotted hole 2.

Correction
–

Loosen the upper counternut at the limit switch 1.

–

Push the limit switch to the very rear of the slotted hole.

–

Tighten the upper counternut again.

Attention: Risk of breakage !

After operations on the limit switch always check the distance to the
switching screw 4.

2.1.2

Distance between switching screw and limit switch

Checking
–

Push the transport carriage 5 to the rear until the switching screw 4
is located under the limit switch 1.

–

Check the distance of 1 mm between limit switch 1 and switching
screw 4.

Correction
–

Loosen the counternut 3 at the switching screw 4.

–

Adjust the height of screw 4.
Distance between switching screw and limit switch = 1 mm.

–

Tighten the counternut 3.

2.1.3

Stop guide for the transport carriage

Checking
–

Push the transport carriage 5 to the rear until the surface of the
switching screw 4 is located centrically above the limit switch 1.

–

Check whether in this transport carriage position the distance
between the stop guide 6 and the transport carriage amounts to 2
mm.

Correction
–

Push the transport carriage to the rear until the surface of the
switching screw 4 is located centrically above the limit switch 1.

–

Loosen the counternut 7.

–

Approach the stop guide 6 to the transport carriage by 2 mm.

–

Tighten the counternut 7.