2.1.1

Position of the limit switch in the slotted hole

Checking

Unscrew the screws 8 and take off the covering cap 9.

Check the position of the limit switch 1 in the slotted hole 2.

Correction

Loosen the upper counternut at the limit switch 1.

Push the limit switch to the very rear of the slotted hole.

Tighten the upper counternut again.

Attention: Risk of breakage !

After operations on the limit switch always check the distance to the
switching screw 4.

2.1.2

Distance between switching screw and limit switch

Checking

Push the transport carriage 5 to the rear until the switching screw 4
is located under the limit switch 1.

Check the distance of 1 mm between limit switch 1 and switching
screw 4.

Correction

Loosen the counternut 3 at the switching screw 4.

Adjust the height of screw 4.
Distance between switching screw and limit switch = 1 mm.

Tighten the counternut 3.

2.1.3

Stop guide for the transport carriage

Checking

Push the transport carriage 5 to the rear until the surface of the
switching screw 4 is located centrically above the limit switch 1.

Check whether in this transport carriage position the distance
between the stop guide 6 and the transport carriage amounts to 2
mm.

Correction

Push the transport carriage to the rear until the surface of the
switching screw 4 is located centrically above the limit switch 1.

Loosen the counternut 7.

Approach the stop guide 6 to the transport carriage by 2 mm.

Tighten the counternut 7.