Photocells for flap scanning – Beisler 100-68 User Manual

Page 78

Advertising
background image

10.

Photocells for flap scanning

Caution: Risk of injury!

Switch the main switch off.
Adjust the reflected light barriers only with the sewing unit switched
off.

Standard and checking

The light spots 2 and 3 of the photocells 1 and 4 must shine on the
reflected foils of the main clamp.

The light spots must hit the reflected foil approx. 1.5 - 2 mm from the
outside edge.
–

Check whether the light beam of the photocells shines on the
reflected foil.

Correction
–

Loosen the screws at the photocell.

–

Adjust the photocell.

–

Tighten the screws at the photocell.

40

4

3

2

1

Advertising