10.

Photocells for flap scanning

Caution: Risk of injury!

Switch the main switch off.
Adjust the reflected light barriers only with the sewing unit switched
off.

Standard and checking

The light spots 2 and 3 of the photocells 1 and 4 must shine on the
reflected foils of the main clamp.

The light spots must hit the reflected foil approx. 1.5 - 2 mm from the
outside edge.

Check whether the light beam of the photocells shines on the
reflected foil.

Correction

Loosen the screws at the photocell.

Adjust the photocell.

Tighten the screws at the photocell.