Beisler 100-68 User Manual

Page 57

Advertising
background image

3.6

Flap clamp

3.6.1

Flap clamp position

Caution: Danger of injury!

Switch the main switch off.

Check and adjust the flap clamp only with the sewing unit switched off.

Standard and checking

The flap clamps 2 must have a distance of 5 mm parallel to the inside
of the main clamp 1.

Close the flap clamp manually.

Check the distance between flap clamp 2 and the inside of main
clamp 1.

Correction

Loosen the screws 4.

Shift the flap clamp holder 3 correspondingly.

Tighten the screws 4.

19

3

2

1

4

3

5 mm

Advertising