2.2.1

Distance between switching screw and limit switch

Checking

Push the transport carriage 7 to the front until the switching screw
4 is located under the limit switch 1.

Check the distance of 1 mm between limit switch 1 and switching
screw 4.

Correction

Loosen the counternut 3 at the switching screw 4.

Adjust the height of screw 4.
Distance between switching screw and limit switch = 1 mm.

Tighten the counternut 3.

2.2.2

Front end position of the transport carriage

Push the transport carriage 7 to the front until the switching screw
4 is located under the limit switch 1.

Measure the distance between the needles and the fronts of the
transport clamp.
This must amount to 325 mm.

Adjust the limit switch 1 in the slotted hole accordingly.

2.2.3

Stop guide for the transport carriage

Checking

Push the transport carriage 7 to the front until the surface of the
switching screw 4 is located centrically above the limit switch 1.

Check whether in this transport carriage position the distance
between the stop guide 6 and the transport carriage amounts to 2
mm.

Correction

Push the transport carriage to the front until the surface of the
switching screw 4 is located centrically above the limit switch 1.

Loosen the counternut 5.

Approach the stop guide 6 to the transport carriage by 2 mm.

Tighten the counternut 5.