Global parameters

The global paramaters comprise the general machine settings.
Alterations will affect all programmed seams.

The following global parameters can be altered:

01 Front feeding point

Distance between feeding position and sewing start.
When the seam length is changed, only the seam end will vary.

Input:

Factory setting:

135 mm

02 Central feeding point

With this setting the seam beginning is calculated in such a way that
seam beginning and seam end are equally shifted when the seam
length is changed.
This is usually required for a hip pocket with dart in case the dart is to
be located in the middle of the pocket.

Input:

Factory setting:

225 mm

03 Rear feeding point

Setting: Distance between feeding position and seam end.
When the seam length is changed, the seam end remains unchanged
and the seam beginning varies.

Input:

Factory setting:

315 mm

04 Folder up after

The time when the folder is swivelled up after sewing.
If the section is set too short, the folder will get caught at the folding
slides.

Input:

Factory setting:

335 mm