Needle change

Caution: Risk of injury!

Switch the main switch off.
Change the needles only when the main switch is switched off.

Risk of cuts!

Do not reach into the area of the centre knife 3 when changing the
needles.

Swivel the folding station aside (see chapter 2.1)
The needles are freely accessible.

Loosen screw 2 and remove needle from needle holder 1.

Push a new needle into the drill-hole of needle holder 1 as far as it
will go.
ATTENTION!
Seen from the operator’s side of the sewing unit the hollow groove
4 of the left needle must point to the left and the hollow groove 5 of
the right neele to the right (see sketch).

Tighten screw 2.

ATTENTION!

After the changeover to another needle size the needle protection at
the hook has to be readjusted (see service instructions).