2.6

Remaining thread monitor

The remaining thread monitor supervises the left and right hook thread
bobbin with the infrared reflected light barriers 1 and 2.

When the bobbin is empty, the light beam emitted by light barrier 1
or 2 is reflected at the free reflecting surface 3 of the bobbin hub.

The display of the control unit indicates the message shown in the
right picture.

The remaining thread in the supply groove of the bobbin hub
guarantees that the pocket opening is safely finished.
The transport carriage stops in its rear end position.

Caution: Risk of injury!

Switch the main switch off.

Clean the lenses of the light barriers only with the sewing unit
switched off.

Switch the main switch off.

When changing the bobbin always clean the lenses of the light
barrier with a soft cloth.

Switch the main switch on.

Start the new sewing process.