2.6

Remaining thread monitor

The remaining thread monitor supervises the left and right hook thread
bobbin with the infrared reflected light barriers 1 and 2.

–

When the bobbin is empty, the light beam emitted by light barrier 1
or 2 is reflected at the free reflecting surface 3 of the bobbin hub.

–

The display of the control unit indicates the message shown in the
right picture.

–

The remaining thread in the supply groove of the bobbin hub
guarantees that the pocket opening is safely finished.
The transport carriage stops in its rear end position.

Caution: Risk of injury!

Switch the main switch off.

Clean the lenses of the light barriers only with the sewing unit
switched off.

–

Switch the main switch off.

–

When changing the bobbin always clean the lenses of the light
barrier with a soft cloth.

–

Switch the main switch on.

–

Start the new sewing process.

1

13

3

2

1