4.4

Guide plates at the folder

Caution: Risk of injury!

Switch the main switch off.

Adjust the guide plates only with the sewing unit switched off.

Standard and checking

The lateral distance between the guide plates 2 and the needles
should be as small as possible. However, the guide plates must not
abut on the needles or the needle holders 3 because this may lead to a
high noise level, damage to the guide plates and the needle head as
well as to thread breakage.

The distance between the sole top 1 and the bottom of the guide plate
2 should not exceed 0.5 mm.
Only when processing especially thick materials the distance has to be
increased.
–

Lower the folder.

–

Check the position of the guide plates as to the needles.

Correction

Aligning the guide plates
–

Cautiously align the guide plates by means of a flat pliers.

Adjusting the height of the guide plates
–

Loosen the counternuts 4 and 5.

–

Adjust the distance of the guide plates 2 with the Allen screws.

–

Tighten the counternuts 4 and 5.

26

3

2

1

5

4