4.4

Guide plates at the folder

Caution: Risk of injury!

Switch the main switch off.

Adjust the guide plates only with the sewing unit switched off.

Standard and checking

The lateral distance between the guide plates 2 and the needles
should be as small as possible. However, the guide plates must not
abut on the needles or the needle holders 3 because this may lead to a
high noise level, damage to the guide plates and the needle head as
well as to thread breakage.

The distance between the sole top 1 and the bottom of the guide plate
2 should not exceed 0.5 mm.
Only when processing especially thick materials the distance has to be
increased.

Lower the folder.

Check the position of the guide plates as to the needles.

Correction

Aligning the guide plates

Cautiously align the guide plates by means of a flat pliers.

Adjusting the height of the guide plates

Loosen the counternuts 4 and 5.

Adjust the distance of the guide plates 2 with the Allen screws.

Tighten the counternuts 4 and 5.

26

3

2

1

5

4