3.5

Folding slides

3.5.1

Adjusting travel and parallelism of the folding slides

Caution: Risk of injury!

Switch the main switch off.

Check and adjust the folding slides only with the sewing unit switched
off.

Standard and checking

According to the needle distance the folding slides 1 and 2 have to be
shifted by the following values when extending and retracting.

Needle distance 10 mm = approx. 3.5 mm

Needle distance 12 mm = approx. 4.5 mm

Needle distance more than 14 mm = max. stroke

Check the distance of the folding slides.

Correction

Loosen the screws 3.

Adjust the cylinder 4 correspondingly.

Align the folding slides in parallel position.

Tighten the screws 3.

Check distance and parallelism of the folding slides once again.