Acquisition Modules and Platinum Firmware

Digitiser Configuration

Select the required digitiser from the menu. The data-terminal program will

suspend any service running on the associated port and start a minicom
session with the correct communications parameters already set.

The use of minicom is described in section 16.3 on page 267. When you have
finished configuring the digitiser, key

+

then

to exit. Any

previously running service will be restarted.

8.2.3 dm24-upgrade

The dm24-upgrade tool provides a command-line facility to upgrade the

firmware on attached CMG-DM24 and CMG-CD24 digitisers. Each release of
Platinum firmware contains the latest firmware images for both digitiser

types. You may wish to upgrade your Platinum firmware (see section 5 on
page 51 for details) before using this command.

To perform a simple upgrade, enter the command

dm24-upgrade id

replacing id with the port identifier (typically PortA or PortB) or the

digitiser's ID (as reported by, for example, the data­terminal command

described in the previous section).

More complex operations are possible; these are invoked by placing

command-line arguments between the command and the port identifier, as in:

dm24-upgrade arguments id

The available arguments are described in the following paragraphs.

­­trashfram

― Perform a hard factory reset, all parameters will be lost.