Guralp Systems CMG-DCM build <10,000 User Manual

Page 132

Advertising
background image

Acquisition Modules and Platinum Firmware

Receiving Data

10.2.1 Configurable parameters in simple mode

The configurable parameters for GCF BRP receiver are contained in a single

form in simple mode:

User description: Sets the name of the service; this should be set to a
meaningful name for the data that it will be receiving, such as the IP or

hostname of the network digitiser.

User label: Identify the particular client instance in log-files (optional).

Enable: Causes this service to start automatically when the system is
re-booted. If this check-box is cleared, the service will need to be started

manually (from the “Control” → “Services” menu)

Delete: Causes the configuration for this instance to be removed from the
system when the form is submitted.

Remote Server: Specify the hostname or IP address of the network digitiser

Remote service: Specify the port (name or number) that the digitiser is

transmitting on.

Allow disconnects: If checked, the instance will attempt to automatically
recover from lost connections by trying to reconnect to the server.

Disable rewind: If checked no attempts will be made to request missing data

blocks. This should only be selected if the server is unable to fulfil such
requests.

MAN-EAM-0003