Acquisition Modules and Platinum Firmware

Initial set-up

If you wish your acquisition module to initiate connections with remote
systems across the Internet, or to be able to access firmware upgrades, you

need to configure a DNS server (also known as a name-server). If you do not
know the address of your DNS server, your Internet Service Provider (ISP)

will be able to tell you. You can also use 8.8.8.8, which is a free, public DNS
server operated by Google Inc. Enter the command

eam999 ~ # echo "nameserver 8.8.8.8" >> /etc/resolv.conf

substituting the address of the required DNS server in place of the example
address (8.8.8.8) shown in the example above.

3.2.4 Connecting to the web interface

The Platinum firmware on all acquisition modules provides a web interface

for configuration and control of the module and connected equipment. While
there are other methods of connecting to the modules, the web interface is

recommended.

Once the IP address of the acquisition module has been set or determined,

enter the it into the address bar of a web browser to connect to the module's
web interface . The examples below are for an EAM address entered into

Firefox and Internet Explorer:

On versions of Platinum from release 10,000, the web interface will initially

show a status display and a brief menu. There is an option to log in on that
menu. Click on the link and enter the default user-name of root and

password of rootme.

If you are connecting to the acquisition module over a network that you

consider insecure (such as the internet), it is recommended that you use the
HTTPS (secure HTTP) protocol, which uses TLS to encrypt the link. Simply

change the http:// prefix to https:// in the browser's address bar. Most
browsers will complain that the certificate cannot be verified: This is not a

problem: simply press the “accept” button to proceed. The link will then be
encrypted and nobody will be able to “sniff the wire” in an attempt to discover

passwords and other data.

Once connected and logged in, you will be presented with the main summary

screen and a much larger menu. The summary screen contains general
information about the status and health of the connected modules and

equipment.

The exact contents and layout of this screen will vary depending on the

configuration of both the acquisition module and of any attached devices.

See section 4on page 33 for information on using the web interface.