background image

Acquisition Modules and Platinum Firmware

Transmitting Data

Note: The QSCD protocol only supports a single instrument. If you need to
transmit results from multiple instruments, you should configure multiple

QSCD sender instances, one for each instrument.

12.5.2 Configurable parameters in expert mode

The following additional configuration parameters are available by clicking
the “Expert” button at the bottom of the form and selecting the 'Advanced' tab.

Log file: It may sometimes be desirable, for debugging purposes, to separate
log messages for this transmitter from the standard system log. The text field

can be populated with a path name which will then be used for dedicated
logging. If left blank, logging occurs (via the standard Linux syslog facility) to
/var/log/messages.

Log level: The drop-down menu controls the level of detail present in log
messages, whether to syslog or to a dedicated log file. Not all of the standard

syslog logging levels are available. The menu offers a choice (in order of
decreasing detail) of:

Debugging information

Informational messages

Important notices

Warnings

GDI multiplexer: In most configurations, all data for all transmitters is taken

from a single multiplexor, as described in section 6.1 on page 65. For more
complex configurations, it is possible to configure multiple multiplexers, each

with their own set of input and output services. In these situations, the
drop-down menu can be used to select a multiplexer instance with which to

associate this transmitter. The menu offers a list of currently configured
multiplexers.

12.6 WIN Sender

WIN is a Japanese seismic data format.