0x22 - cmr control - variable length – NavCom LAND-PAK Rev.N User Manual

Page 43

Advertising
background image

Technical Reference Manual Rev. N

Blk = All;

Blu = IOP w/Internal Radio

;

Red = IOP & LBM

;

Grn = Engine only

41

0x22 - CMR Control - Variable Length

Request output of CMR message 0, 1 and 2.

1. Wn1 through Wn2 is repeated for each block, as applicable. CMR0 is the Observables.
CMR1 is the reference station’s position. CMR2 is the description of the reference site.

2. No blocks come out if the reference position has not been installed with message

0x51 (Self Survey Block).

3. These blocks require a RTK Base license for sending and a RTK Rover license for

receiving

4. The 0x5f message can be used to configure a wrapper port using the ‘C’ preamble.

Record
Usage

Command - Yes
Response - No

For CMR: (Wn1,Wn2,Wn3) should be (0x00, 0x00, 0x0nnn), (0x01, 0x00, 0x00nn)
For CMR+: (Wn1, Wn2, Wn3) should be (0x05, 0x00, 0x0001)

Ref

Message Field Description

Data Type Units

Range

Scale

Byte

Count

STX

02

(hex)

U08

1

PRA1 99 (hex)

U08

1

PRA2 66 (hex)

U08

1

ID

22

(hex)

U08

1

Length

0x00xx

U16

2

W1

Command Action

B1=1: Store in NVRAM

B3=1: Use default values

B4=1: Clear all present CMR

messages

U08

1

W2

Reserved

U08

1

Repetitive Blocks
Wn1

CMR message ID

U08

1

Wn2 Reserved

U08

1

Wn3

Data rate

0x0000: Turns off the message

0x0001: to 0x1fff Data Rate

0x2xxx: is not used

0x4000: on Change

0x8xxx: is not used

U16

seconds



Hz


n seconds

1

2

CKSM Checksum

U08

1

ETX

03

(hex)

U08

1