Technical Reference Manual Rev. N

Blk = All;

Blu = IOP w/Internal Radio

;

Red = IOP & LBM

;

Grn = Engine only

76

0x73 - Radio configuration Control Block - Variable Length

This Block is actually multiple blocks sharing the same ID and multiple sub ID’s.

Present data is requested using a special 0x73 message rather than the more conventional
message 0x20. The request command appears as follows:

Request

Record
Usage

Command - Yes
Response - Yes

Input: sets the internal radio operation;
Output: reports the current internal radio settings

Ref

Message Field Description

Data Type Units

Range

Scale

Byte

Count

STX

02

(hex)

U08

1

PRA1 99 (hex)

U08

1

PRA2 66 (hex)

U08

1

ID

73

(hex)

U08

1

Length 0x0008

U16

2

W1

0x00

U08

1

W2

0x00 Sub ID

U08

1

W3

Block Request
0x01: Operation Mode

(Master/Slave)

0x02: Radio Power Setting

0x04: FEC
0x08: HOP Pattern
0x10: HOP Interval
0x20: Packet Control
0x40: Roam Control
0x80: Remote Control

U08

1

Port
B0=1: Diagnostic Port
B1=1: Control Port
B2=1: Data Port
B3=1: Network Port
B4-B7: Reserved

U08

1

CKSM Checksum

U08

1

ETX

03

(hex)

U08

1

0x73 continued on next page