0x75 - transmit envelope - variable length – NavCom LAND-PAK Rev.N User Manual

Page 85

Advertising
background image

Technical Reference Manual Rev. N

Blk = All;

Blu = IOP w/Internal Radio

;

Red = IOP & LBM

;

Grn = Engine only

83

0x75 - Transmit Envelope - Variable Length

This message is used to address a message to a specific NCT integrated receiver on an
available network (i.e. turn off RTK base function on a distant unit).

Record
Usage

Command - Yes
Response - No

Input: sets the remote internal radio operation;

Ref

Message Field Description

Data Type Units

Range

Scale

Byte

Count

STX

02

(hex)

U08

1

PRA1 99 (hex)

U08

1

PRA2 66 (hex)

U08

1

ID

75 (hex)

U08

1

Length 0x0xxx

U16

2

W1

Reserved

U08

1

W2

HOP count - Number of HOPS

U08

1

W3

To Address: Ghost ID of Unit

(Radio ID)

Unit uses internal block if
Address matches (W3)

Otherwise, Slave Rebroadcasts

message and Increments

HOP count, if HOP equals

0 (Master will rebroadcast with

HOP count at 0 or 1, all

messages not addressed to it).

All Units will match to broadcast
ID (0xc350, decimal

50000)

U16

2

W4

From Address: Ghost ID of the Unit

to respond to

U16

2

W5

Internal Block

B1: Command ID
B2: Msg. Len.

B3: W1

Bn:

Wm

end of internal

message
Checksum

U08
U16


U08

1
2


1

CKSM Checksum

U08

1

ETX

03

(hex)

U08

1

Advertising