6

If the DC power input is 53V, the unit will aggregate the power with the AC power

input, if any.


Follow below steps to wire the redundant or aggregated DC power inputs.

1. Insert positive and negative wires into V+ and V- contacts respectively of the

terminal block connector.

2. Tighten the wire-clamp screws to prevent DC wires from being loosened.
3. DC1 and DC2 support polarity reverse protection functions.

Note 1: It is a good practice to turn off input and load power. Otherwise, your

screwdriver blade can inadvertently short your terminal connections to the
grounded enclosure.

Note 2: The range of the suitable electric wire is from 12 to 22 AWG.
Note 3:
The unit will alarm for loss of power, for instance, PSU, DC1 or DC2.

2.3

Power Supply Specifications

Power Supply

Type

Input Range

Fuse

Rating

Max. Power

Consumption

Min

Max

All Ethernet Ports

48 VDC

46 VDC

57 VDC

10A(T)

28W

HI (250 VDC)

HI (110/230

VAC)

127 VDC

90 VAC

370 VDC

264 VAC

4A(T)

Table: Power Supply Specifications