Command lines of the warning configuration – Westermo MRI-128-F4G-PSE24 User Manual

Page 149

Advertising
background image

145

Command Lines of the Warning configuration

Feature

Command Line

Relay Output

Relay Output

Switch(config)# relay 1

dry dry output

ping ping failure

port port link failure

power power failure

ring super ring failure

Dry Output

Switch(config)# relay 1 dry

<0-4294967295> turn on period in second

Switch(config)# relay 1 dry 5

<0-4294967295> turn off period in second

Switch(config)# relay 1 dry 5 5

Ping Failure

Switch(config)# relay 1 ping 192.168.2.200

<cr>

reset reset a device

Switch(config)# relay 1 ping 192.168.2.200 reset

<1-65535> reset time

Switch(config)# relay 1 ping 192.168.2.200 reset

60

<0-65535> hold time to retry

Switch(config)# relay 1 ping 192.168.2.200 reset

60 60

Port Link Failure Switch(config)# relay 1 port

PORTLIST port list

Switch(config)# relay 1 port fa1-5

Power Failure

Switch(config)# relay 1 power

<1-3> power id (1: AC, 2: DC1, 3:DC2)

any Anyone power failure asserts relay

Switch(config)# relay 1 power 1

Switch(config)# relay 1 power 2

Super Ring Failure Switch(config)# relay 1 ring

Disable Relay

R. Switch(config)# no rel1 relay id

Switch(config)# no relay 1 (Relay_ID: 1 or 2)

<cr>

Display

Switch# show relay 1

Advertising
This manual is related to the following products: