Wiring digital output, Wiring earth ground – Westermo MRI-128-F4G-PSE24 User Manual

Page 11

Advertising
background image

7

MRI-128-F4G-P24

Power

Supply

Type

Input Range

Fuse

Rating

Power Consumption

Min

Max

Worst

Case

Max

48 VDC

46 VDC 57 VDC 1.5A(F)

369.6W

369.6W

53 VDC

52 VDC 57 VDC 1.5A(F)

568W

720W

Table: PoE/PoE Plus Power Supply Specifications

Note 1: (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
Note 2: Power consumption varies based on configuration. 10/100Tx ports

consume roughly 1W less than fiber optic ports

Note 3: For continued protection against risk of fire, replace only with same

type and rating of fuse.

2.4

Wiring Digital Output

The switch provides one digital output, also known as Relay Output. The relay
contacts are energized (open) for normal operation and will close for fault

conditions. The fault conditions include power failure, Ethernet port link break
or other pre-defined events which can be configured.

Wiring digital output is exactly the same as wiring power input introduced in
chapter 2.2.

2.5

Wiring Earth Ground

To ensure the system will not be damaged by noise or any electrical shock, we

suggest you to make exact connection with the switch with Earth Ground.

On the back panel, there is one earth ground screw. Loosen the earth ground

screw using a screw driver; then tighten the screw after earth ground wire is

connected.