Preparation for management 3.1, Preparation for serial console, 3 preparation for management – Westermo MRI-128-F4G-PSE24 User Manual

Page 16

Advertising
background image

12

3 Preparation for Management

The switch provides both in-band and out-band configuration methods. You

can configure the switch via RS232 console cable if you don’t attach your admin

PC to your network, or if you lose network connection to the switch. This is

so-called out-band management. It wouldn’t be affected by network
connectivity. The in-band management means you can remotely manage the
switch via the network. You can choose Telnet or Web-based management.

You just need to know the device’s IP address and you can remotely connect to

its embedded HTTP web pages or Telnet console.Following topics are covered
in this chapter:


3.1 Preparation for Serial Console

3.2 Preparation for Web Interface

3.3 Preparation for Telnet console

3.1

Preparation for Serial Console

In the package, Westermo attached one RS-232 DB-9 console cable. Please

attach RS-232 DB-9 connector to your PC COM port, connect to the Console
port of the the switch. If you lose/lost the cable, please follow the console

cable PIN assignment to find a new one, or contact your closest Westermo
sales office. (Refer to the appendix).

1. Go to Start -> Program -> Accessories -> Communication -> Hyper Terminal
2. Give a name to the new console connection.

3. Choose the COM name

4. Select correct serial settings. The serial settings of The switch are as below:

Baud Rate: 9600 / Parity: None / Data Bit: 8 / Stop Bit: 1

5. After connected, you can see Switch login request.

6. Log into the switch. The default username is “admin”, password,

“westermo”.

Switch login: admin
Password:

The switch (version 1.1-20101014-11:04:13).

Switch>

Advertising
This manual is related to the following products: