Disable Port

Mirror

Switch(config)# mirror disable

Mirror set disable ok.

Select Source Port Switch(config)# mirror source fa1-2

both Received and transmitted traffic

rx Received traffic

tx Transmitted traffic

Switch(config)# mirror source fa1-2 both

Mirror source fa1-2 both set ok.

Note: Select source port list and TX/RX/Both

mode.

Select Destination

Port

Switch(config)# mirror destination fa6

Mirror destination fa6 set ok

Display

Switch# show mirror

Mirror Status : Enabled

Ingress Monitor Destination Port: fa6

Egress Monitor Destination Port: fa6

Ingress Source Ports :fa1,fa2,

Egress Source Ports :fa1,fa2,

Event Log

Display

Switch# show event-log

<1>Jan 1 02:50:47 snmpd[101]: Event: Link 4

Down.

<2>Jan 1 02:50:50 snmpd[101]: Event: Link 5 Up.

<3>Jan 1 02:50:51 snmpd[101]: Event: Link 5

Down.

<4>Jan 1 02:50:53 snmpd[101]: Event: Link 4 Up.

Ping

Ping IP

Switch# ping 192.168.2.33

PING 192.168.10.33 (192.168.2.33): 56 data bytes

64 bytes from 192.168.2.33: icmp_seq=0 ttl=128

time=0.0 ms

64 bytes from 192.168.2.33: icmp_seq=1 ttl=128

time=0.0 ms

64 bytes from 192.168.2.33: icmp_seq=2 ttl=128

time=0.0 ms

64 bytes from 192.168.2.33: icmp_seq=3 ttl=128

time=0.0 ms