Westermo MRI-128-F4G-PSE24 User Manual

Page 69

Advertising
background image

65

Status : Enabled

Host 1 :

Target IP : 192.168.2.100

Cycle Time : 10
Host 2 :

Target IP : 192.168.2.200

Cycle Time : 20
Host 3 :

Target IP : 192.168.2.15

Cycle Time : 30

Host 4 :
Target IP : 192.168.2.20

Cycle Time : 40

Syntax

show poe schedule IFNAME

Parameters

IFNAME : interface name

Command Mode

Enable mode

Description

Display the status of schedule of interface.

Examples

Switch# show poe schedule fa1

Interface fastethernet1

POE Schedule
Status : Disable

Weekly Schedule :
Sunday : 0,1,2,3,4,5,6,7,8,19,20,21,22,23

Monday : 0,1,2,3,4,5,6,7,8,19,20,21,22,23
Tuesday : 0,1,2,3,4,5,6,7,8,19,20,21,22,23

Wednesday : 0,1,2,3,4,5,6,7,8,19,20,21,22,23
Thursday : 0,1,2,3,4,5,6,7,8,19,20,21,22,23

Friday : 0,1,2,3,4,5,6,7,8,19,20,21,22,23

Saturday

:

0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20

Syntax

poe powering-mode 802.3af/forced

Parameters

802.3af: deliver power if and only if the attached PD

comply with IEEE 802.3af

forced: deliver power no maater what PD attached

Command Mode

Interface mode

Description

Set the Powring mode of PoE

Examples

EX 1: Set 802.3af powring mode

Switch(config)# poe powering-mode 802.3af

Advertising