4.4.2 Emergency Power Management

The switch is equipped with dual 48VDC power inputs for providing true network

redundancy. An alarm relay output signals when a power input fails or other
critical events occur. To ensure reliable power delivery, other advanced PoE

power management features include individual port status monitoring,

emergency power management (3 power supply indication inputs for quick

shutdown of ports according to pre-defined priority table in cases where power
supply failure occurs) and voltage/current monitoring and regulation. Power
management allows the switch to determine the exact power draw per port and

to balance each port PoE power output accordingly. This, in turn, allows the

switch to power higher and lower wattage devices according to user-definable
parameters such as maximum available power, port priority (critical, high, low),

and maximum allowable power per port. For the same level priority, the priority
order is decided by port number. The port number sequence of

MRI-128-F4G-PSE/24 from high priority to low priority is 3-4-1-2-7-8-5-6-

11-12-9-10-15-16-13-14-19-20-17-18-23-24-21-22-27-28-25-26.

4.4.3 PD Status Detection

The switch delivers a useful function – PD Status Detection. This provides
automatic detection of a remote device powered by the switch. If the remote

system crashes or is unstable, the switch will perform a system reboot by turning
off and on again to trigger the remote device. The following figure shows the Web

configure interface for Power over Ethernet PD Status Detection.

You can enable/disable PD Status Detection function and type in the IP address

that you want to detect. The Cycle Time is the gap per detection. After

configuring, please click the Apply button to enable and perform the functions.