T2-01: PM Motor Auto-Tuning Mode Selection

No.

Name

Setting Range

Default

T2-01

PM Motor Auto-Tuning Mode Selection

0 to 2; 14

0

Setting 0: PM Motor Parameter Settings
Setting 1: PM Stationary Auto-Tuning
Setting 2: PM Stationary Auto-Tuning for Stator Resistance
Setting 14: PM Rotational Auto-Tuning

n

T2-02: PM Motor Code Selection

If the drive is operating a Yaskawa PM motor from the SMRA, SSR1, or SST4 series, enter the motor code in T2-02 to

automatically set parameters T2-03 through T2-14. If the drive is operating a specialized motor or a motor designed by a

manufacturer other than Yaskawa, set T2-02 to FFFF and enter the data from the motor nameplate or the motor test report as

prompted.
Only the designated PM motor codes may be entered. The PM motor codes accepted by the drive will differ depending on the

selected control mode.

No.

Name

Setting Range

Default

T2-02

PM Motor Code Selection

0000 to FFFF

Determined by A1-02

and o2-04

n

T2-03: PM Motor Type

Selects the type of PM motor the drive will operate.

No.

Name

Setting Range

Default

T2-03

PM Motor Type

0, 1

1

Setting 0: IPM motor

Setting 1: SPM motor

n

T2-04: PM Motor Rated Power

Specifies the motor rated power in kilowatts.

No.

Name

Setting Range

Default

T2-04

PM Motor Rated Power

0.00 to 650.00 kW

Determined by o2-04

n

T2-05: PM Motor Rated Voltage

Sets the motor rated voltage.

No.

Name

Setting Range

Default

T2-05

PM Motor Rated Voltage

0.0 to 255.0 V

<1>

200.0 V

<1>

<1> Value shown is specific to 200 V class drives. Double value for 400 V class drives.

n

T2-06: PM Motor Rated Current

Enter the motor rated current in amps.

No.

Name

Setting Range

Default

T2-06

PM Motor Rated Current

0.0% to 300.0% of the

drive rated current.

Determined by o2-04

n

T2-07: PM Motor Base Frequency

Enter the motor base frequency in Hz.

Note:

T2-07 will be displayed when in OLV/PM.

No.

Name

Setting Range

Default

T2-07

PM Motor Base Frequency

0.0 to 400.0 Hz

87.5 Hz

4.8 Auto-Tuning

YASKAWA ELECTRIC TOEP C710636 10B Z1000U HVAC MATRIX Drive User Manual