Motor with Brake

Take caution when using the drive to operate a motor with a built-in holding brake. If the brake is connected to the output side

of the drive, it may not release at start due to low voltage levels, so be sure to install a separate power supply for the motor

brake. Note that motors with built-in brakes tend to generate a fair amount of noise when running at low speeds.

n

Notes on Power Transmission Machinery

Installing an AC drive in machinery that was previously connected directly to the power supply will allow the machine to

operate at variable speeds. Continuous operation outside of the rated speeds can wear out lubrication material in gear boxes

and other power transmission parts. Make sure that lubrication is sufficient within the entire speed range to avoid machine

damage. Note that operation above the rated speed can increase the noise generated by the machine.

u

Drive Label Warning Example

Always heed the warning information listed in

Figure i.2

.

WARNING

Read manual before installing.

Wait 5 minutes for capacitor

discharge after disconnecting

power supply.

To conform to requirements,

make sure to ground the supply

neutral for 400V class.

After disconnecting from power

supply,please wait 5 minutes

before inspecting, performing

maintenance or wiring the

converter.

Risk of electric shock.

Hot Surfaces

Wait 5 minutes or longer

until the unit has cooled.

Figure i.2 Warning Information Example and Position

i.2 General Safety