T2: pm motor auto-tuning – Yaskawa Z1000U User Manual

Page 307

Advertising
background image

u

T2: PM Motor Auto-Tuning

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

T2-01

(0750)

PM Motor Auto-Tuning

Mode Selection

PM Tuning Mode

0: Standard Tuning

1: Tune-No Rotate

2: Term Resistance

14: PM Rotation

Tune

OLV/PM

OLV/PM

0: PM Motor Parameter Settings

1: PM Stationary Auto-Tuning

2: PM Stationary Auto-Tuning for Stator Resistance

14: PM Rotational Auto-Tuning

Default: 0

Range: 0 to 2;

14

T2-02

(0751)

PM Motor Code

Selection

PM Mtr Code Sel

OLV/PM

OLV/PM

Enter the motor code when using a Yaskawa PM motor. After

entering the motor code, the drive automatically sets parameters

T2-03 through T2-09. Set parameters T2-10 to T2-14 according

the motor nameplate or the motor test report. When using a motor

without a supported motor code or a non-Yaskawa motor, set

FFFF and adjust the other T2 parameters according to the motor

nameplate or the motor test report.

Default:

<1>

Min: 0000

Max: FFFF

T2-03

(0752)

PM Motor Type

PM Motor Type

0: IPM motor

1: SPM motor

OLV/PM

OLV/PM

0: IPM motor

1: SPM motor

Default: 1

Range: 0, 1

T2-04

(0730)

PM Motor Rated Power Mtr Rated Power

OLV/PM

OLV/PM

Sets the motor rated power.

Note:

Use the following formula to convert horsepower

into kilowatts:

1HP = 0.746 kW.

Default:

<4>

Min.: 0.00 kW

Max.: 650.00

kW

T2-05

(0732)

PM Motor Rated

Voltage

Rated Voltage

OLV/PM

OLV/PM

Enter the motor rated voltage as indicated on the motor nameplate.

Default: 200.0
V

<5>

Min.: 0.0
Max.: 255.0

<5>

T2-06

(0733)

PM Motor Rated Current Rated Current

OLV/PM

OLV/PM

Enter the motor rated current as indicated on the motor nameplate.

Default:

<4>

Min.: 10% of

drive rated

current

Max.: 150% of

drive rated

current

T2-07

(0753)

PM Motor Base

Frequency

Base Frequency

OLV/PM

OLV/PM

Enter the motor base frequency as indicated on the motor

nameplate.

Default: 87.5

Hz

Min.: 0.0

Max.: 400.0

T2-08

(0734)

Number of PM Motor

Poles

Number of Poles

OLV/PM

OLV/PM

Enter the number of motor poles for the PM motor as indicated

on the motor nameplate.

Default: 6

Min.: 2

Max.: 48

T2-10

(0754)

PM Motor Stator

Resistance

Arm Resistance

OLV/PM

OLV/PM

Enter the rotor resistance for the PM motor as indicated on the

motor nameplate.

Default:

<3>

Min.: 0.000 Ω

Max.: 65.000 Ω

T2-11

(0735)

PM Motor d-Axis

Inductance

d-Axis Induct

OLV/PM

OLV/PM

Enter the d-axis inductance for the PM motor as indicated on the

motor nameplate.

Default:

<3>

Min.: 0.00 mH

Max.: 600.00

mH

T2-12

(0736)

PM Motor q-Axis

Inductance

q-Axis Induct

OLV/PM

OLV/PM

Enter the q-axis inductance for the PM motor as indicated on the

motor nameplate.

Default:

<3>

Min.: 0.00 mH

Max.: 600.00

mH

T2-13

(0755)

Induced Voltage

Constant Unit Selection

Iduct Volt Unit

0: mV/RPM

1: mV/(rad/sec)

OLV/PM

OLV/PM

0: mV/(r/min). E5-09 will automatically be set to 0.0, and E5-24

will be used.

1: mV/(rad/sec). E5-24 will automatically be set to 0.0, and E5-09

will be used.

Default: 1

Range: 0, 1

B.13 T: Motor Tuning

YASKAWA ELECTRIC TOEP C710636 10B Z1000U HVAC MATRIX Drive User Manual

307

B

Parameter List

Advertising
This manual is related to the following products: