Yaskawa Z1000U User Manual

Page 198

Advertising
background image

The rated output current of the drive is too small Use a larger drive.

HOA Keypad Display

Fault Name

oFA00

Option Card Connection Error at Option Port CN5-A
Option compatibility error

Cause

Possible Solution

The option card installed into port CN5-A is

incompatible with the drive

Check if the drive supports the option card to be installed. Contact Yaskawa for assistance.

HOA Keypad Display

Fault Name

oFA01

Option Card Fault at Option Port CN5-A
Option not properly connected

Cause

Possible Solution

The option card connection to port CN5-A is faulty

• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure the card is fixed

properly.

HOA Keypad Display

Fault Name

oFA03 to oFA06

Option Card Error Occurred at Option Port CN5-A

oFA10, oFA11

oFA12 to oFA17

Option Card Connection Error (CN5-A)

oFA30 to oFA43

Communication Option Card Connection Error (CN5-A)

Cause

Possible Solution

Option card or hardware is damaged

• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a

Yaskawa representative for instructions on replacing the control board.

HOA Keypad Display

Fault Name

oFb00

Option Card Fault at Option Port CN5-B
Option compatibility error

Cause

Possible Solution

The option card installed into port CN5 is

incompatible with the drive

Check if the drive supports the option card to be installed. Contact Yaskawa for assistance.

HOA Keypad Display

Fault Name

oFb01

Option Card Fault at Option Port CN5-B
Option not properly connected

Cause

Possible Solution

The option card connection to port CN5-B is faulty

• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure the card is fixed

properly.

HOA Keypad Display

Fault Name

oFb02

Option Card Fault at Option Port CN5-B
Same type of option card is currently connected

Cause

Possible Solution

An option card of the same type is already installed

in option port CN5-A

Only one of each option card type can only be installed simultaneously. Make sure only one type of

option card is connected.

An input option card is already installed in option

port CN5-A

Install a communication option, a digital input option, or an analog input option. More than one of

the same type of card cannot be installed simultaneously.

HOA Keypad Display

Fault Name

oFb03 to oFb11

Option card error occurred at Option Port CN5-B

oFb12 to oFb17

Cause

Possible Solution

5.4 Fault Detection

198

YASKAWA ELECTRIC TOEP C710636 10B Z1000U HVAC MATRIX Drive User Manual

Advertising
This manual is related to the following products: