B.13 T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance.

u

T1: Induction Motor Auto-Tuning

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

T1-01

(0701)

<1>

Auto-Tuning Mode

Selection

Tuning Mode Sel

2: Term Resistance

3: On-

DelayCompTune

2: Stationary Auto-Tuning for Line-to-Line Resistance

3: Rotational Auto-Tuning for V/f Control Energy Saving

Default: 2

Range: 2, 3

135

T1-02

(0702)

Motor Rated Power

Mtr Rated Power

Sets the motor rated power as specified on the motor nameplate.

Note:

Use the following formula to convert horsepower

into kilowatts: 1HP = 0.746 kW.

Default:

<2>

Min.: 0.00 kW

Max.: 650.00

kW

135

T1-03

(0703)

Motor Rated Voltage

Rated Voltage

Sets the motor rated voltage as specified on the motor nameplate. Default: 200.0

V

<3>

Min: 0.0
Max: 255.0

<3>

136

T1-04

(0704)

Motor Rated Current

Rated Current

Sets the motor rated current as specified on the motor nameplate. Default:

<2>

Min.: 10% of

drive rated

current

Max.: 200% of

drive rated

current

136

T1-05

(0705)

Motor Base Frequency Rated Frequency

Sets the rated frequency of the motor as specified on the motor

nameplate.

Default: 60.0

Hz

Min.: 0.0

Max.: 400.0

136

T1-06

(0706)

Number of Motor Poles Number of Poles

Sets the number of motor poles as specified on the motor

nameplate.

Default: 4

Min.: 2

Max.: 48

136

T1-07

(0707)

Motor Base Speed

Rated Speed

Sets the rated speed of the motor as specified on the motor

nameplate.

Default: 1750 r/

min

Min.: 0

Max.: 14400

136

T1-11

(070B) Motor Iron Loss

Mtr Iron Loss(W)

Sets the iron loss for determining the Energy Saving coefficient.

The value is set to E2-10 (motor iron loss) set when the power is

cycled. If T1-02 is changed, a default value appropriate for the

motor capacity that was entered will appear.

Default:

<4>

Min.: 0

Max.: 65535

136

T1-12

(FFF0) T1 Tuning Start

Tuning Ready

The drive starts tuning.

No setting

available

136

<1> The availability of certain Auto-Tuning methods depends on the control mode selected for the drive.
<2> Default setting is dependent on parameter o2-04, Drive Model Selection.
<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives.
<4> Default setting value differs depending on the motor code value, motor parameter settings, and E2-11, Motor Rated Power.

B.13 T: Motor Tuning

306