4 connecting to sgdv, E5a servopack (command option attachable type), 1) sgdv-fe5a – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 100

Advertising
background image

3 Wiring and Connection

3.2.4 Connecting to SGDV-E5A SERVOPACK (Command Option Attachable Type)

3-16

3.2.4 Connecting to SGDV-



E5A SERVOPACK (Command

Option Attachable Type)

(1) SGDV-FE5A

∗1. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗2. For connection to the command option module, refer to the user’s manual of the corre-

sponding option module.

∗3. The connected device and cable depend on the model of the linear scale.

R T

Option module*

2

External LED indicator,

external device, etc.

SGDV-

FE5A

SERVOPACK

Power supply

Single-phase 100 VAC

Noise filter

Molded-case

circuit breaker

(MCCB)

Used to eliminate

external noise from

the power line.

Magnetic contactor

Turns the servo

ON and OFF.

Install a surge

absorber.

Regenerative

resistor*

1

When not using the safety

function, use the SERVOPACK

with the safety function jumper

connector (JZSP-CVH05-E,

provided as an accessory)

inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

I/O signal cable

Connection cable

for digital operator

Connection cable

for personal computer

Digital

operator

Personal

computer

Protects the power

supply line by

shutting the circuit

OFF when

overcurrent is

detected.

Linear servomotor

main circuit cable

Serial converter unit

*

3

Cable for connecting a

serial converter unit

*

3

Linear servomotor

with core

Linear scale

(Not included)

Cable for connecting a

hall sensor

Cable for connecting a

linear scale

*

3

Advertising