Using a single-phase, 200-v power supply – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 98

Advertising
background image

3 Wiring and Connection

3.2.3 Connecting to SGDV-25 SERVOPACK (M-III Model)

3-14

Using a Single-phase, 200-V Power Supply

The

Σ-V Series SERVOPACK for a 200-V power supply input has input specifica-

tions for a three-phase power supply, but some models can also be used with a single-
phase 200-V power supply. For details, refer to

Σ

-V Series User's Manual Design and

Maintenance Linear Motor/MECHATROLINK-III Communications Reference
(No.: SIEP S800000 65).

∗1. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗2. The connected device and cable depend on the model of the linear scale.

R

T

Noise filter

Molded-case

circuit breaker

(MCCB)

Magnetic contactor

I/O signal cable

SGDV-

A25

SERVOPACK

Power supply

Single-phase 200 VAC

Protcts the power supply

line by shutting the

circuit OFF when

overcurrent is detected.

Used to eliminate

external noise from

the power line.

Turns the servo

ON and OFF.

Install a surge

absorber.

Personal

computer

Connection cable

for personal computer

Digital

operator

When not using the safety

function, use the SERVOPACK

with the safety function jumper

connector (JZSP-CVH05-E,

provided as an accessory)

inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

Connection cable

for digital operator

Host controller

Regenerative

resistor*

1

Connect to the

MECHATROLINK-III

Linear servomotor

main circuit cable

Serial converter unit

*

2

Cable for connecting a

serial converter unit

*

2

Linear servomotor

with core

Linear scale

(Not included)

Cable for connecting a

hall sensor

Cable for connecting a

linear scale

*

2

Advertising