2) new model, 4safety function, Connect a safety function device to cn8 – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 136

Advertising
background image

4.5 Connecting a Safety Function Device

4-7

4

Safety Function

(2) New Model

1.

Remove the safety function’s jumper connector from CN8.

2.

Connect a safety function device to CN8.

Note:When not using the safety function, use the SERVOPACK with the safety function’s

jumper connector (JZSP-CVH05-E provided as an accessory) inserted in CN8. If
the SERVOPACK is used without the jumper connector inserted into CN8, no cur-
rent will flow to the servomotor and no force will be output. In this case, "Hbb" will
be displayed on the panel operator or the digital operator.

C
N
8

C
N
2

C
N
1

C

N

8

C

N

2

Enlarged View

Safety function’s
jumper connector

Hold the jumper connector with
two fingers and pull it out.

Advertising