4.5 Connecting a Safety Function Device
4-7
4
Safety Function
(2) New Model
1.
Remove the safety function’s jumper connector from CN8.
2.
Connect a safety function device to CN8.
Note:When not using the safety function, use the SERVOPACK with the safety function’s
jumper connector (JZSP-CVH05-E provided as an accessory) inserted in CN8. If
the SERVOPACK is used without the jumper connector inserted into CN8, no cur-
rent will flow to the servomotor and no force will be output. In this case, "Hbb" will
be displayed on the panel operator or the digital operator.
C
N
8
C
N
2
C
N
1
C
N
8
C
N
2
Enlarged View
Safety function’s
jumper connector
Hold the jumper connector with
two fingers and pull it out.