2installation – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 83

Advertising
background image

2.5 EMC Installation Conditions

2-61

2

Installation

Three-phase 400 V, SGDV-260D25A

∗1. Products that have received CE marking are recommended for the 24 VDC power supply.

∗2. Install the following noise filter on the power line between the single-phase 200 V power

supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)

∗3. For more information on this filter, refer to

Σ

-V Series Product Catalog (No.: KAEP

S800000 42).

Symbol

Cable Name

Specification

I/O signal cable

Shield cable

Cable for safety unit

Shield cable

Linear servomotor main circuit cable

Shield cable

Linear scale connection cables

Shield cable

Control power cable

Shield cable

Main circuit cable

Shield cable

Regenerative resistor unit cable

Non-shield cable

MECHATROLINK-III communication cable Shield cable

CN2

1

2

3

6

5

8

7

4

U, V, W

L1, L2, L3

B1, B2

24 V,
0 V

CN1

PE

PE

CN8

CN6A, CN6B

MECHATROLINK-III

controller

SERVOPACK

Safety unit

Linear

scale

Linear

servomotor

Power supply:

Single-phase

200 VAC

Power supply:

Three-phase

400 VAC

Shield box

Clamp

Clamp

Clamp

Clamp

Clamp

Noise

filter*

3

Regenerative

resistor unit

Surge

absorber

Surge

absorber

Surge

absorber

Noise

filter*

2

Control

power

supply

24 VDC*

1

Clamp

Clamp

Clamp

Host controller

Advertising