5.4 Execution of Origin Setting (Fn020)

5-13

5

T

rial Operation (Checking Linear Servomotor Operation)

∗ With SGDV SERVOPACK that support MECHATROLINK-II or MECHATROLINK-III,

“A.941” will not be shown, and “BB” will be displayed instead.

Using the Panel Operator

4

Press the

Key to start the ori-

gin setting. During origin setting,

“Scale Origin Set” will be displayed

blinking.

When the origin setting is

completed, the display stops

blinking, and the status will be
changed as BB

→DONE→A.941

.

5

Turn OFF the power to the SERVOPACK and then ON again to enable the setting.

(cont’d)

Step

Display after operation

Keys

Operation

B B

S c a l O r i g i n S e t

Step Display after operation

Keys

Operation

1

Press the MODE/SET Key to select the Util-

ity Function mode.

2

Press the UP or DOWN Key to select Fn020.

3

Press the DATA/SHIFT Key for approxi-

mately one second. The display shown on

the left will appear.

4

Keep pressing the UP Key until 0SET5

appears.

Note:

If the correct key is not properly pressed,

No_oP will be displayed blinking and the

display will return to that of step 1.

5

(Displayed blinking)

Press the MODE/SET Key to set the scale

origin.

When the origin is set, donE is displayed

blinking for approximately one second.

6

One second after

The display donE is changed to OSET5.

7

Press the DATA/SHIFT Key for approxi-

mately one second. The display will return to

Fn020.