2) main circuit power input, 3) servopack main circuit wires – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual
Page 112

3 Wiring and Connection
3.3.3 When Using the SERVOPACK with a Single-phase 200 V Power Input
3-28
(2) Main Circuit Power Input
Connect a single-phase 200 V power supply of the following specifications to L1
and L2 terminals.
The specifications of the power supplies other than the
main circuit power supply are the same as for three-phase power supply
input
.
(3) SERVOPACK Main Circuit Wires
Terminal
Symbols
Terminal Name
Model
SGDV-A
Ratings
L1, L2
Main circuit power
input terminals
R70, R90, 1R6,
2R8, 5R5
Single-phase 200 V to 230 V,
+10% to
−15% (50/60Hz)
L3
*
–
None
∗ Do not use L3 terminal.
Terminal
Symbols
Terminal Names
形式
SGDV-A
R70
R90
1R6
2R8
5R5
L1, L2
Main circuit power input ter-
minals
HIV1.25
HIV2.0
L1C, L2C
Control power input terminals
HIV1.25
U, V, W
Linear servomotor connection
terminals
HIV1.25
HIV
2.0
B1/
, B2
External regenerative resistor
connection terminals
HIV1.25
Ground terminal
HIV2.0 or higher