3.2 System Configuration Diagram

3-17

3

Wiring and Connection

(2) SGDV-AE5A

Using a Three-phase, 200-V Power Supply

∗1. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗2. For connection to the command option module, refer to the user’s manual of the corre-

sponding option module.

∗3. The connected device and cable depend on the model of the linear scale.

R S T

Option module*

2

External LED indicator,

external device, etc.

SGDV-

AE5A

SERVOPACK

Noise filter

Molded-case

circuit breaker

(MCCB)

Protects the power supply

line by shutting the

circuit OFF when

overcurrent is

detected.

Used to eliminate

external noise from

the power line.

Magnetic contactor

Turns the servo

ON and OFF.

Install a surge

absorber.

Regenerative

resistor*

1

When not using the safety

function, use the SERVOPACK

with the safety function jumper

connector (JZSP-CVH05-E,

provided as an accessory)

inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

I/O signal cable

Connection cable

for digital operator

Connection cable

for personal computer

Digital

operator

Personal

computer

Power supply

Three-phase 200 VAC

Linear servomotor

main circuit cable

Serial converter unit

*

3

Cable for connecting a

serial converter unit

*

3

Linear servomotor

with core

Linear scale

(Not included)

Cable for connecting a

hall sensor

Cable for connecting a

linear scale

*

3