3wiring and connection, 2 system configuration diagram 3-9 – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 93

Advertising
background image

3.2 System Configuration Diagram

3-9

3

Wiring and Connection

(2) SGDV-A15

Using a Three-phase, 200-V Power Supply

∗1. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗2. The connected device and cable depend on the model of the linear scale.

R S T

Connect to the

MECHATROLINK-II

SGDV-

A15

SERVOPACK

Power supply

Three-phase 200 VAC

Noise filter

Molded-case

circuit breaker

(MCCB)

Protects the power

supply line by shutting

the circuit OFF when

overcurrent is detected.

Used to eliminate

external noise from

the power line.

Magnetic

contactor

Turns the servo

ON and OFF.

Install a surge

absorber.

Regenerative

resistor*

1

When not using the safety function,

use the SERVOPACK with the safety

function jumper connector

(JZSP-CVH05-E, provided as

an accessory) inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

I/O signal cable

Connection cable

for digital operator

Connection cable

for personal computer

Digital

operator

Personal

computer

Host controller

Linear servomotor

main circuit cable

Serial converter unit

*

2

Cable for connecting a

serial converter unit

*

2

Linear servomotor

with core

Linear scale

(Not included)

Cable for connecting a

hall sensor

Cable for connecting a

linear scale

*

2