Using a single-phase, 200-v power supply – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 90

Advertising
background image

3 Wiring and Connection

3.2.1 Connecting to SGDV-05 SERVOPACK (Analog Pulse Model)

3-6

Using a Single-phase, 200-V Power Supply

The

Σ-V Series SERVOPACK for a 200-V power supply input has input specifica-

tions for a three-phase power supply, but some models can also be used with a single-

phase 200-V power supply. For details, refer to

Σ

-V Series User's Manual Design and

Maintenance Linear Motor/Analog Voltage and Pulse Train Reference (No.: SIEP

S800000 47).

∗1. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-

necting Regenerative Resistors.

∗2. The connected device and cable depend on the model of the linear scale.

R S T

SGDV-

A05

SERVOPACK

Power supply
Single-phase 200 VAC

Noise filter

Molded-case

circuit breaker

(MCCB)

Protects the power supply

line by shutting the

circuit OFF when

overcurrent is

detected.

Used to eliminate

external noise from

the power line.

Magnetic

contactor

Turns the servo

ON and OFF.

Install a surge

absorber.

Regenerative

resistor*

1

When not using the safety

function, use the SERVOPACK

with the safety function jumper

connector (JZSP-CVH05-E,

provided as an accessory) inserted.

When using the safety function,

insert a connection cable

specifically for the safety function.

Safety function

devices

I/O signal cable

Connection cable

for digital operator

Connection cable

for personal computer

Digital

operator

Personal

computer

Host controller

Linear servomotor

main circuit cable

Serial converter unit*

2

Cable for connecting a

serial converter unit*

2

Linear servomotor

with core

Linear scale

(Not included)

Cable for connecting a

hall sensor

Cable for connecting a

linear scale*

2

Advertising