2 Installation

2.5.1 SGDV-05 (Analog Pulse Model)

2-38

2.5

EMC Installation Conditions

This section describes the recommended installation conditions that satisfy EMC
guidelines for each model of the SGDV SERVOPACK. The conditions required for
the standard type (base-mounted) of SERVOPACK are described. Refer to this sec-
tion for other SERVOPACK models such as the rack-mounted types as well.

This section describes the EMC installation conditions satisfied in test conditions
prepared by Yaskawa. The actual EMC level may differ depending on the actual sys-
tem’s configuration, wiring, and other conditions. However, because this product is
built-in, check that the following conditions are still met after being installed in the
user’s product.

The applicable standards are EN55011 group 1 class A, EN61800-3, and
EN61000-6-2.

2.5.1 SGDV-05 (Analog Pulse Model)

Single-phase 100 V, SGDV-F05A ( = R70, R90, 2R1,
2R8)

Symbol

Cable Name

Specification

I/O signal cable

Shield cable

Cable for safety unit

Shield cable

Linear servomotor main circuit cable

Shield cable

Linear scale connection cables

Shield cable

Main circuit cable

Shield cable

Power supply:

Single-phase

100 VAC

U, V, W

L1, L2

L1C, L2C

CN2

CN1

Shield box

SERVOPACK

PE

PE

Linear

scale

Linear

servomotor

1

3

4

5

Clamp

Noise

filter

Clamp

Clamp

Clamp

CN8

2

Surge

absorber

Two turn

One turn

Core

Core

Core

Core

Core

Core

Two turn

Two turn

Clamp

Host

controller

Safety unit

One turn