3.3 Main Circuit Wiring

3-37

3

Wiring and Connection

2.

Strip the end of the wires.

3.

Open the wire terminal on the terminal connector housing with a tool,
using the following methods. Either method can be used to open the
wire terminal.

• Using a spring opener

Use the spring opener provided with the SERVOPACK to open the wire
terminal as shown in the diagram.

Note: The spring opener (1981045-1) made by Tyco Electronics AMP K.K. can also be used.

• Using a screwdriver

Use a commercially available flat-blade screwdriver with a blade width of 3.0
to 3.5 mm. Insert the screwdriver into the slot and press down firmly to open the
wire terminal.

4.

Insert the wire core into the opening, and then secure the wire into
position by removing the opener or screwdriver to close the opening.

5.

Make all the required connections in the same way.

6.

Attach the connector to the SERVOPACK.

Applicable wire sizes:

8 to 9 mm

Refer to 3.3.2 (2) SERVO-
PACK Main Circuit Wires.

Wire

Spring opener

Advertising