3 installation conditions for applicable standards – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 26

Advertising
background image

2 Installation

2.1.3 Installation Conditions for Applicable Standards

2-4

• Mounting Near a Vibration Source

To prevent vibration from being transmitted to the SERVOPACK, install a vibration

isolator underneath the SERVOPACK.

• Mounting to a Location Exposed to Corrosive Gas

Take measures to prevent exposure to corrosive gas. Corrosive gases will not imme-

diately affect the SERVOPACK, but will eventually cause electronic components and
contactor-related devices to malfunction.

• Other Locations

Do not mount the SERVOPACK in locations subject to high temperatures, high
humidity, dripping water, cutting oil, dust, iron filings, or radiation.

Note: When storing the SERVOPACK with the power OFF, store it in an environment with the

following temperature and humidity:

• -20

°C to +85°C, 90% RH or less. (with no condensation)

2.1.3 Installation Conditions for Applicable Standards

Applicable

Standards

UL508C

EN50178, EN55011 group1 class A, EN61000-6-2, EN61800-3, EN61800-

5-1, EN954-1, IEC61508-1 to 4

Operating

Conditions

Overvoltage Category: III

Pollution degree: 2

Protection class: IP10

Installation

Conditions

UL Standard and Low Voltage Directive:

Satisfy the conditions outlined in

Σ

-V Series AC SERVOPACK SGDV Safety

Precautions (No.: TOBP C710800 10)

EMC Directive:

Certification is required after installation in the user’s machine under the

conditions outlined in 2.5 EMC Installation Conditions of this manual.

Advertising