4 connecting regenerative resistors, 1 connecting regenerative resistor, Warning – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 122

Advertising
background image

3 Wiring and Connection

3.4.1 Connecting Regenerative Resistor

3-38

3.4

Connecting Regenerative Resistors

If the capacity to absorb regenerative energy is insufficient, use the following proce-
dure to connect an external regenerative resistor and set the regenerative resistor
capacity in the parameter Pn600.

To learn how to select a regenerative resistor, and for detailed specifications, refer to

Σ

-V Series Product Catalog (No.: KAEP S800000 42).

3.4.1 Connecting Regenerative Resistor

This section describes how to connect a regenerative resistor.

(1) SERVOPACKs: Model SGDV-R70F, R90F, 2R1F, 2R8F, R70A, R90A,

1R6A, or 2R8A

Connect an external regenerative resistor between B1/ and B2 terminals. After
connecting a resistor, set the regenerative resistor capacity. Refer to 3.4.2 Setting the
Regenerative Resistor Capacity
for information on how to set the regenerative resis-
tor capacity.

WARNING

• Be sure to connect the regenerative resistor correctly. Do not short-circuit

between B1/

⊕ and B2.

Failure to observe this warning may result in fire or damage to the regenerative resistor or

SERVOPACK.

Enlarged View