3) sgltm (4) sglcm – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual
Page 52
Advertising
2 Installation
2.3.1 Installation Conditions
2-30
(3) SGLTM
(4) SGLCM
Magnetic Way
Model
SGLTM-
Distance from Magnetic Way
X (mm)
Y (mm)
Z (mm)
20
70
50
20
35A
80
55
25
35H
85
60
25
50
85
65
30
40
110
80
35
80
120
80
40
Z
Z
X
Y
Magnetic Way
Model
SGLCM-
Distance from Magnetic Way
X (mm)
Y, Z (mm)
D16
80
60
D20
100
70
D25
125
95
D32
160
115
Z
X
Y
Advertising