2installation – Yaskawa Sigma-5 User Manual: Setup for Linear Motors User Manual

Page 75

Advertising
background image

2.5 EMC Installation Conditions

2-53

2

Installation

Three-phase 400 V, SGDV-260D15A

∗1. Products that have received CE marking are recommended for the 24 VDC power supply.

∗2. Install the following noise filter on the power line between the single-phase 200 V power

supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)

∗3. For more information on this filter, refer to

Σ

-V Series Product Catalog (No.: KAEP

S800000 42).

Symbol

Cable Name

Specification

I/O signal cable

Shield cable

Cable for safety unit

Shield cable

Linear servomotor main circuit cable

Shield cable

Linear scale connection cables

Shield cable

Control power cable

Shield cable

Main circuit cable

Shield cable

Regenerative resistor unit cable

Non-shield cable

MECHATROLINK-II communication cable Shield cable

U, V, W

L1, L2, L3

24 V, 0 V

CN2

CN1

Linear

scale

PE

PE

Linear

servomotor

1

2

3

6

5

CN8

Clamp

Clamp

MECHATROLINK-II

controller

CN6A, CN6B

8

Clamp

B1, B2

7

4

SERVOPACK

Safety unit

Power supply:

Single-phase

200 VAC

Power supply:

Three-phase

400 VAC

Shield box

Clamp

Clamp

Clamp

Clamp

Noise

filter*

3

Surge

absorber

Surge

absorber

Noise

filter*

2

Control

power

supply

24 VDC*

1

Clamp

Regenerative

resistor cable

Host

controller

Advertising