Slope trigger, Slope trigger -20 – RIGOL MSO/DS2000A Series User Manual

Page 106

Advertising
background image

RIGOL

Chapter 5 To Trigger the Oscilloscope

5-20

MSO2000A/DS2000A User’s Guide

Slope Trigger


Trigger on the positive or negative slope which satisfies the specified condition.

Trigger Type:
Press Type, rotate

to select “Slope” and press down

. At this point, the

trigger setting information is displayed at the upper right corner of the screen. For

example,

. The trigger type is slope trigger; the trigger source is

CH1; the difference between the upper limit of trigger level and the lower limit of
trigger level is 1.24 V.

Source Selection:

Press Source to switch the signal source list between CH1 and CH2. For the details,

please refer to the introduction in Trigger Source. The current trigger source is

displayed at the upper right corner of the screen.

Note:

Select channel with signal input as trigger source to obtain stable trigger.


Slope Condition:
In this oscilloscope, positive slope time is defined as the time difference between the
two crossing points of trigger level line A and B with the rising edge; negative slope
time is defined as the time difference between the two crossing points of trigger level
line A and B with the falling edge as shown in the figure below.





Figure 5-6 Positive Slope Time/Negative Slope Time


Press When to select the desired slope condition.

: trigger when the positive slope time of the input signal is greater than

the specified time.

: trigger when the positive slope time of the input signal is lower than the

specified time.

: trigger when the positive slope time of the input signal is greater than

the specified lower limit of time and lower than the specified upper limit of time.

Up Level

Low Level

A

B

Positive Slope Time

Negative Slope Time

Advertising