Chapter 6 MATH and Measurements
6-16
MSO2000A/DS2000A User’s Guide
below.
8. Phase 1 →2 : phase difference calculated according to “Delay 1 →2 ” and
the period of source 1, expressed in degree. The calculation formula is as shown
below.
The phase calculation formula:
360
1
Delay
Phase
Period
=
×
°
Wherein,
Phase
represents the pahase measurement result
Delay
represents the delay measurement result
1
Period
represents the period of source 1